Simple operation
AUTO set up for instant use
Ultra fast pulse for near end fault
identification
Trace HOLD feature to allow comparison
between cables
IP54 rating offers real life working
Designed for use on all metallic cable
pairs
DESCRIPTION
The TDR1000/3P is a hand held, compact Time Domain Reflectometer
for locating faults on metallic cables. It has a minimum resolution
of 0.1 m/0.3 ft and a 5 km/15 kft maximum range depending on
velocity factor selected and cable type.
Four output impedances are available (25, 50, 75, and 100 Ω) and
a velocity factor between 0.2 and 0.99 will meet any cable test
requirements
The TDR1000 has a simple selection option which together with a 4
way control switch offers an intuitive operation for the user.
FEATURES AND BENIFITS
An AUTO selection option ensures that the most effective parameters
are selected depending on the range required, aiding rapid diagnosis
of the TDR trace. Dual cursors allow complete flexibility, giving the
operator full control and instant indication of distance between two
points.
A trace HOLD feature also allows comparison between conditions,
something not seen on most other handheld TDRs. Extra high
resolution together with white-light backlight and grey scale tones
give the graphical display a vibrancy, aiding the user in identifying
key events on the trace.
n
Backlit graphics monochrome LCD (256 x 128)
n
Adjustable display contrast
n
Resolution to 0.1 m
n
For use on Telecom TNV-3 circuit, or 150 V CAT IV power
circuits
n
Power blocking filter not required
n
Environmental protection to IP54
n
Auto selected output impedance
(between 25, 50, 75 and 100 Ω)
n
2 ns pulse for near end fault location
n
AUTO option selecting gain and pulse for each range
n
Display distance in metres or feet
n
Uses five AA (LR6) primary cells
SALES OFFICE
Megger Limited
Archcliffe Road Dover
CT17 9EN England
T +44 (0) 1304 502101
E UKsales@megger.com
TDR10003P_DS_en_V07
www.megger.com
ISO 9001
The word ‘Megger’ is a registered trademark
TDR1000/3P
Handheld TDR
SPECIFICATIONS
Range
10 m, 25 m, 100 m, 250 m,
1000 m, 2500 m, 5000 m
(30 ft, 75 ft, 300 ft, 750 ft,
3000 ft, 7500 ft, 15000 ft)
Accuracy
±1% of range ± pixel at 0.67 VF
[Note- The measurement accuracy is for the indicated cursor
position only and is conditional on the velocity factor being correct.]
Resolution
1% of range
Input protection
This instrument complies with
IEC61010-1 for connection to live
systems up to 150 V CAT IV when
used with the supplied fused test
lead set.
Output pulse
5 volts peak to peak into open circuit.
Pulse widths determined by range
and cable
Gain
Set for each range with three user
selectable steps (in Manual
operating mode)
Velocity factor
Variable from 0.2 to 0.99 in steps
of 0.01
TX null
Automatic
Power down
Automatic after 5 minutes with
no key press
Backlight
Stays on for 1 minute with
no key press
Battery
Five LR6 (AA) type batteries,
Manganese alkali or nickel
metal-hydride cells
Battery life
Up to 14 hours (Typical)
Dimensions
230 x 115 x 48 mm
( 9.0 x 4.5 x 2.0 inches)
Weight
0.6 kg (1.32 lbs)
ORDERING INFORMATION
Description
Part number
Time Domain Reflectometer
1001-789
Description
Part number
Included accessories
Hard case
User guide CD
Retractable sheath fused test lead (1 pair)
Optional accessories
Miniature clip test lead set (1 pair)
6231-652
Red and black probes and clips -
for use with all Megger TDR Fused Test Leads.
1002-491
Split conductor fused test lead set (1 pair)
1002-015
Case
ABS
Connectors
Two 4 mm-safety terminals
Test lead
(19 mm spaced TDR1000/3P):
1 pair 1.5 m retractable sheath,
fitted with 500 mA FF HBC 1 kV
50 kA fuse
Display
256 x 128 pixel Graphics LCD
Operating temperature range and humidity
-15 °C to +50 °C (5 °F to 122 °F)
Storage temperature range and humidity
-20 °C to 70 °C (-4 °F to 158 °F)
Safety
When using the supplied fused test
lead set this instrument complies with
IEC61010-1 for connection to live
systems with less than 300 V
between the terminals and up to
150 V CAT IV to earth
EMC
Complies with Electromagnetic
Compatibility Specifications
(Light industrial) BS EN 61326-1,
with a minimum performance of
‘B’ for all immunity tests